Manufacturer
C100
Stainless-steel competition perimeter gutter available with drop-in or top grating and optional deck-drain or evacuator chamber configurations.

Selected configuration
316L Stainless - Drop-In Grating
C100-316-DI · Part C100-316-DI · SKU C100-316-DI
Changing the configuration updates the exact values, imagery, files, and compatibility context below.
- Configuration Type
- DI
- Deck Drain
- No
- Evacuator Chamber
- No
- Grating Span
- 11.75 in
- Gutter Depth
- 12.875 in
- Grating Style
- drop-in
Files for 316L Stainless - Drop-In Grating
Configuration-specific files are listed first.
C100 316L Drop-In Grating Configuration Drawing
Specification · PDF · This configuration
C100 304L Drop-In Grating CAD Drawing
CAD · DWG · All configurations
C100 304L Top Grating CAD Drawing
CAD · DWG · All configurations
Technical specifications
Core product data stays visible
Configuration-specific values are separated from the product-wide specification, so important family data never disappears behind a disclosure.
38 visible fields
Selected configuration
316L Stainless - Drop-In Grating
Grating
- Grating Surface
- textured slip-resistant
- Grating Thickness
- 1 in
- Grating Material
- HDPE
- Grating Style
- drop-in
Configuration
- Configuration Type
- DI
- Deck Drain
- No
- Evacuator Chamber
- No
Dimensions
- Grating Span
- 11.75 in
- Gutter Depth
- 12.875 in
General
- Equipment Type
- stainless steel perimeter gutter
- Gutter Series
- C100
Materials
- Construction Material
- 316L stainless steel
Specifications
- Material
- 316L stainless steel
- Model Number
- C100-316-DI
- Anchor Spacing
- 1 ft from corners and 4 ft on center
- Continuous Sealant
- Yes
- Custom Engineering Available
- Yes
- Deck Return
- 6
- Deck Return Width In
- 6
- Deck Side Flange Width
- 3
- Deck Side Flange Width In
- 3
- Deck Slab Depth Reference In
- 4
- Drawing Geometry Verified
- Yes
- Drawing Verified
- Yes
- Expansion Joint
- 0.5
- Expansion Joint Width In
- 0.5
- Grating Span In
- 11.75
- Gutter Anchor Type
- 5/8 in U-bar
- Gutter Section Depth In
- 12.875
- Nylon Inlet Nozzles
- Yes
- Perimeter Overflow
- Yes
- Pool Finish Anchor Offset
- 4.5
- Pool Finish Anchor Offset In
- 4.5
- Reference Deck Depth
- 4
- Return Tube
- Yes
- Source Document
- C100-316-DI.pdf
- Stainless Steel Grade
- 316L
- Stainless Steel Stiffener Channel
- Yes
Configuration comparison
Compare what actually changes
Use this when you need to compare configurations. The main technical specification above remains the primary product record.
8 of 8 configurations
| Configuration | Handhold Width | Configuration Type | Construction Material | Deck Drain | Resources |
|---|---|---|---|---|---|
| Not listed | DI | 316L stainless steel | No | 7 | |
| Not listed | DI | 304L stainless steel | No | 7 | |
| 0.5 in | TG | 304L stainless steel | No | 7 | |
| 0.5 in | TG | 316L stainless steel | No | 7 | |
| 0.5 in | TGDD | 304L stainless steel | Yes | 7 | |
| 0.5 in | TGDD | 316L stainless steel | Yes | 7 | |
| 0.75 in | TGEC | 304L stainless steel | No | 7 | |
| 0.75 in | TGEC | 316L stainless steel | No | 7 |
Documents
Resources for 316L Stainless - Drop-In Grating
Configuration-specific files appear first. Product-wide documents remain available because they apply across the family.
7 applicable documents
C100 316L Drop-In Grating Configuration Drawing
Specification · PDF
Specification
This configuration
C100 304L Top Grating with Evacuator Chamber CAD Drawing
CAD · DWG
CAD
All configurations
System context

Manufacturer
Paddock Pool Equipment Company
Rock Hill, South Carolina
The Paddock C100 is a stainless-steel competition perimeter gutter system offered in 304L and 316L stainless steel. Configuration drawings document drop-in grating, standard top grating, top grating with an integrated deck-drain chamber, and top grating with an extra or evacuator chamber. Drawing details identify a one-inch-thick textured HDPE grate, SCRS pan, return tube, nylon inlet nozzles, stainless-steel stiffener channel, continuous sealant, expansion joint, and anchored concrete installation. Final project dimensions and fabrication requirements should be confirmed against the applicable Paddock configuration drawing and project submittal.